• Digital data processing controlled by microprocessor
and microcontroller.
• 500w 5A dimming or Relay per ch.
•Opto-fired Triac output devices
• Solid state thyristor phase control(scr[2/Ch]or triac)
• ‘DMX-In’ LED for DMX-512 signal indication
• Up to 16 program recalling.
Dimming or switching each channel can be set to be a switching only (non-dimming)
• Dimming or switching each channel can be set to be a switching only (non-dimming
• Single or three phase operation
• Dimmer will hold last DMX value for a set time should control data be interrupted
• 1024-step fade resolution for all fade and cross-fade functions
- 4 Dry contact Input for general purpose
• Variable fade rates from 0 seconds to 1 hours
• RS485 Interface: LMX, RS232 Interface to PC
• Support Interface analog 0-10 Volte
• Internal temperature controlled DC fan
• 24-hr 7-day in-built event timer (battery backed)
Power supply type : 1-Phase,2 Wires 200-240 Vac 50 Hz.
Dissipation : <1.0% of output load
Operating temp : 40°C max for output load.
Dimmer curve : Square law B
Control input : LMX protocol (Lighting multiplexer) [Support RS485] and DMX- 512(USITT1990)
Output connectors : Terminal Blocks
Input -Output signal : 3-pin XLR